Artificial hip joint

Removal of cutter marks after ball-end milling process

Effects after installation

BEFORE

Tool
Sandpaper
Problem
Manual processing caused uneven surface.

AFTER

Tool
Effect
Fully automated polishing enabled complete removal of cutter marks. Surface quality improved.

Workpiece information

Industry
Medical
Part name
Artificial hip joint
Material type
Titanium alloy
Cutting process
Ball End mill processing

Processing conditions

Tool
Processing detail
Removal of cutter marks after ball-end milling process
Rotation speed(min-1)
4,000
Feed, feed rate(mm/min)
1,500
Depth of cut (mm)
0.4
Machining time (sec)
-

CASE STUDY TOP